光明理化学工業株式会社ロゴ
中文 Japanese
Products
RETURN TO TOP OF Application Specific.

Flue Gas Sampler

P-10FG
Image1 To measure gas sample from a gas duct such as Nitrogen oxides, Sulphur dioxide, Oxygen and to prevent pollution easily and quickly.
■ Compotision
■ Detector tubes to measure flue gas
Substances to be measured Tube No. Measuring range
CARBON MONOXIDE (CO) 106SA 5-2,000ppm
CARBON DIOXIDE (CO2) 126SH 1-20%
HYDROGEN CHLORIDE 173SA 20-1,200ppm
NITROGEN OXIDES 174B NO;10-300ppm,
NO2;1-40ppm
NITROGEN OXIDES 175SA 20-250ppm
NITROGEN OXIDES 175SH 100-2,500ppm
OXYGEN 159SC 1.5-24%
SULPHUR DIOXIDE 103SF 0.02-0.3%