| Model |
TPA-5200P |
| Measuring Gas |
Hydrogen Sulphide |
| Measuring Principle |
Chronoamperometry |
| Sampling Method |
Diffusion type |
| Measuring Range |
0.0-50.0ppm |
| Resolution |
0.1ppm |
| Indication accuracy |
0.0-30.0ppm:±1.5ppm, Above 30.1ppm:±3.0ppm |
| Alarm Concentration |
Low:10ppm, High:30ppm |
| Response Time |
Within 25 seconds at 90% response |
| Alarm Method |
LCD display, LED Lamp, vibration and buzzer |
| Power supply |
2 x size "AAA" Alkaline batteries |
| Continuous Operation time |
Alkaline batteries : approx. 600 hrs |
| Operating Temperature Range |
-10-40°C; 15-85%RH(non-condencing) |
| Dimensions |
100 (W) X 54 (H) X 23 (D)mm (excluding sensor enclosure) |
| Weight |
Approx. 100g (including batteries) |
| Standard Accessories |
Softcase |
| Optional Accessories |
Sensor cord for remote measurement(5m, 10m, 20m or 30m) |