Oxygen Monitor
| Model | OMA-600E |
|---|---|
| Measuring Gas | Oxygen in the air |
| Measuring Principle | Galvanic cell |
| Sampling method | Diffusion type |
| Measuring Range | 0.0-50.0vol% |
| Resolution | 0.1vol% |
| Detectable accuracy | Within ±0.5vol% O2 at 0.0-25.0vol% Within ±3.0vol% O2 at over 25.1vol% |
| Display | LCD |
| Alarm concentration | Below 18.0vol% |
| Alarm Method | LED lamp, LCD, buzzer(intermittent sound:over 100dB/10cm) |
| Explosion proof | ExiaII CT4X |
| Response Time | Within 15 seconds at 90% response |
| Power Supply | 3 x AA size alkaline dry battery |
| Continuous Operating time | Approx. 2000 hrs, no alarm |
| Operating Temperature Range | -10-40°C; 30-85%RH (non-condensing) |
| Main body dimensions | 160(W) x 178(H) x 65(D)mm |
| Main body weight | Approx. 740g (including batteries and sensor cord) |
| Standard accessories | 5m sensor cord, carrying case |
| Optional accessories | Sensor cord in 10m, 20m or 30m, softcase |